AV-2000B2
AOKAI
Availability: | |
---|---|
Quantity: | |
Characteristic
Large colored LCD,big font display,free changheable angles of views
Nine gear temperate control system with heating protection function
Respiratory
Product parameters
Display method:
High definition 8.4 TFT color LCD screen display:IPPV、SIPPV、SIMV、PEEP、MANU、SIGH
Ventilation parameters:
tidal volume:50~1500ml
frequency:2-99times/minute
I/E:2:1~1:8
SIMV frequency:2~20times/minute
Inspiratory trigger pressure:-1.0~2.0 kPa
PEEP:0~2.0 kPa
pressure control:1.0~6.0 kPa
sigh:1.5 times suction time
Inspiratory platform:0~50%
oxygen concentration:45%~100%
Ventilation monitoring:
Tidal volume, ventilation volume, IPPV frequency, SIMV frequency, total respiratory rate, inspiratory to expiratory ratio, peak airway pressure, average airway pressure, pressure time waveform, flow rate time waveform, positive end expiratory pressure, inspiratory trigger pressure, inspiratory plateau, oxygen concentration.
security alarm system:
oxygen concentration:
Upper limit setting range 50%~100%
Lower limit setting range 15%~50%
Airway pressure alarm:
Upper limit setting range 1.0~6.0 kPa
Lower limit setting range 0.4~2.0 kPa
Minute ventilation alarm:
Upper limit setting range 3.0~30 L/min
Lower limit setting range 1.0~10 L/min
Continuous high voltage alarm:Alarm when the pressure continues to exceed 2.5 kPa
Apnea alarm:Sound and light alarm within 15 seconds of no tidal volume input
Power outage alarm
power supply:AC 220V±10%;50Hz±1Hz;UPS power supply
storage battery
Characteristic
Large colored LCD,big font display,free changheable angles of views
Nine gear temperate control system with heating protection function
Respiratory
Product parameters
Display method:
High definition 8.4 TFT color LCD screen display:IPPV、SIPPV、SIMV、PEEP、MANU、SIGH
Ventilation parameters:
tidal volume:50~1500ml
frequency:2-99times/minute
I/E:2:1~1:8
SIMV frequency:2~20times/minute
Inspiratory trigger pressure:-1.0~2.0 kPa
PEEP:0~2.0 kPa
pressure control:1.0~6.0 kPa
sigh:1.5 times suction time
Inspiratory platform:0~50%
oxygen concentration:45%~100%
Ventilation monitoring:
Tidal volume, ventilation volume, IPPV frequency, SIMV frequency, total respiratory rate, inspiratory to expiratory ratio, peak airway pressure, average airway pressure, pressure time waveform, flow rate time waveform, positive end expiratory pressure, inspiratory trigger pressure, inspiratory plateau, oxygen concentration.
security alarm system:
oxygen concentration:
Upper limit setting range 50%~100%
Lower limit setting range 15%~50%
Airway pressure alarm:
Upper limit setting range 1.0~6.0 kPa
Lower limit setting range 0.4~2.0 kPa
Minute ventilation alarm:
Upper limit setting range 3.0~30 L/min
Lower limit setting range 1.0~10 L/min
Continuous high voltage alarm:Alarm when the pressure continues to exceed 2.5 kPa
Apnea alarm:Sound and light alarm within 15 seconds of no tidal volume input
Power outage alarm
power supply:AC 220V±10%;50Hz±1Hz;UPS power supply
storage battery